A little over two years ago, a shipping container-sized cylinder bearing Microsoft’s name and logo was lowered onto the ocean floor off the northern coast of Scotland. Earlier this summer, marine specialists reeled up a shipping-container-size datacenter coated in algae, barnacles and sea anemones from the seafloor. The retrieval launched the final phase of a years-long effort that proved the concept of underwater datacenters is feasible, as well as logistically, environmentally and economically practical.

Inside were 864 servers, and their submersion was part of the second phase of the software giant’s Project Natick. Launched in 2015, the project’s purpose is to determine the feasibility of underwater data centers powered by offshore renewable energy. The results not only showed that using these offshore submerged data centers seems to work well in terms of performance, but also revealed that the servers contained within the data center proved to be up to eight times more reliable than their dry-land counterparts.

The team hypothesized that a sealed container on the ocean floor could provide ways to improve the overall reliability of data centers. On land, corrosion from oxygen and humidity, temperature fluctuations and bumps and jostles from people who replace broken components are all variables that can contribute to equipment failure. According to the United Nations, about 40% of the world’s population lives within 60 miles of an ocean. As internet connectivity expands to cover most of the globe in the next few years, millions of more people will come online, and a lot more servers will be needed to manage the increased demand and data they’ll generate.

Servers generate a lot of heat, and data centers use most of their electricity for cooling. Keeping not just the temperature but also the humidity level constant is important for optimal functioning of the servers; neither of these varies much 100 feet underwater. Other advantages included being able to operate with greater power efficiency, especially in regions where the grid on land is not considered reliable enough for sustained operation. The container was filled with dry nitrogen upon deployment, which seems to have made for a much better environment than the oxygen that land-bound servers are normally surrounded by; the failure rate of the servers in the water was just one-eighth that of Microsoft’s typical rate for its servers on land.

The final step in this phase of Project Natick is to recycle all the components used for the underwater data center, including the steel pressure vessel, heat exchangers, and the servers themselves—and restoring the sea bed where the cylinder rested back to its original condition.